Hydro Annual Maintenance

Annual Cleaning/31–Point Inspection: 

1. Run and test machine

2. Inspect pump, pressure valve, plumbing and cooler unit for signs of leakage

3. Inspect cover sheet and comfort pad for rips or tears

4. Clean vents on cooler unit

5. Remove side panels 

6. Remove black knobs and flat bar retainers

7. Remove, inspect, clean or replace barrier

8. Inspect net for tears

9. Inspect/adjust cable tension (replace if necessary) 

10. Remove all water from machine with shopvac 

11. Clean all areas of the tub 

12. Clean shaft seal cover box

13. Clean heater tube

14. Remove water from level sensor tube

15. Inspect jets for debris

16. Inspect and clean 4 wheels on manifold and make sure they spin freely

17. Inspect all hose clamps- inside and outside bed to make sure they are tight

18. Inspect manifold hose for wear

19. Hand check for loose hardware fasteners inside and outside of tank

20. Inspect for discolored or loose wire connections inside control box

21. Inspect interior/exterior hoses

22. Refill bed with appropriate amount of distilled water

23. Add defoamacide 

24. Reassemble machine  

25. Log hours of use

26. Inspect touch screen and perform hard reset

27. Run pressure test

28. Run speed test

29. Run area massage test

30. Run hold position test

31. Check for critical software/mainboard updates 

Hydro Quarterly Maintenance

Have the professionals keep your Hydromassage unit in peak performance. Every 3 months one of our technicians will 

-Add 2-4 gallons of distilled water with defoamacide. 

-Check/adjusted cable or belt tension 

-Full reboot of bed and screen 

-Test massage and inspected for leaks